ATEX and Pneumatic vacuum cleaners




An ATEX-certified industrial vacuum cleaner must abide by some constructive features to prevent any ignition source. The vacuum cleaner must prevent the formation of static electricity and this goal can be reached by choosing constructive options such as grounding, antistatic filters, accessories for the suction of conductive materials, specific and certified engines to avoid overheating. ATEX industrial vacuum cleaners are constructed to operate in full compliance with ATEX regulations in force, by ensuring maximum operational safety.

It is known that ATEX is a complicated but here is simple selection guide for Delfin ATEX certified units:

ATEX 22 certified vacuum cleaners - Atex II 3D marking for use in areas with low risk of explosion due the presence of potentially flammable dusts. Antistatic class M filters and grounding as standard.

ATEX 20 internal/22 external certified vacuum cleaners - Atex II 1/3D marking for use in areas with medium risk of explosion due to the presence of potentially flammable dusts. Antistatic class M filters, HEPA filter H14, grounding and stainless steel container as standard, components and engines certified by the manufacturer. The inner chamber of the vacuum cleaner is certified for zone 20.

ATEX 20 internal/21 external certified vacuum cleaners - Atex II 1/2D marking for use in areas with high risk of explosion due to the presence of potentially flammable usts. Antistatic class M filters, HEPA filter H14, grounding and stainless steel container as standard, components and engines certified by the manufacturer. The inner chamber of the vacuum cleaner is certified for zone 20.

Compressed air Atex certified vacuum cleaners for zone 1, 2, 21, 22 - Atex 2GD marking

Atex certified vacuum cleaners for use in areas of high risk of explosion where electric supply is not available or not recommended. M antistatic filters, earth grounding and stainless steel construction as standard.

Industrial vacuums for combustible dusts Atex or NRTL certified vacuum cleaners for combustible dust extraction. Available with dust inertization system or with internal vacuum certification.

 


Get more information:



Options available:

  • Low risk dusts ATEX 22 certified vacuum cleaners - Atex II 3D marking
  • Medium risk dusts ATEX 20 internal/22 external certified vacuum cleaners - Atex II 1/3D marking
  • High risk dusts ATEX 20 internal/21 external certified vacuum cleaners - Atex II 1/2D marking
  • Compressed air Atex certified vacuum cleaners for zone 1, 2, 21, 22 - Atex 2GD marking
  • Industrial vacuums for combustible dusts
  • INERT RANGE INDUSTRIAL VACUUM CLEANERS FOR COMBUSTIBLE DUST EXTRACTION for aluminum, inconal, lithium, tantalum or zirconium
  • PRE-SEPARATOR FOR THE INERTIZATION OF HAZARDOUS EXPLOSIVE DUSTS
  • Equipped with 1,1 to 18,5 kw single and three-phase motors
  • Vacuum till 4500 mm H2O
  • Tank capacity goes up to 220 liters
  • Wide range of available accessories
  • Extractable collection container
  • Cartrige filter elements with pneumatic jet celaning
  • HEPA filters
  • Compressed air driven units available


Your benefits at a glance:

  • Antistatic class M filters and grounding as standard
  • INERT RANGE units immerse material in an inert liquid
  • Three phase units available with side channel blower motor, powerful and silent, totally maintenance free, suitable for continuous duty
  • Single phase units equipped with brushless motors
  • Heavy duty steel construction
  • Filter with largest surface in its category equipped with integrated manual or automatic cleaning system
  • Pressure relief valve for motor protection
  • Vacuum gauge to detect filter clogging
  • Forklift straps
  • Easy filter replacement
  • Low noise level
  • Compact and mobile
  • Long lasting

Options available:

  • Low risk dusts ATEX 22 certified vacuum cleaners - Atex II 3D marking
  • Medium risk dusts ATEX 20 internal/22 external certified vacuum cleaners - Atex II 1/3D marking
  • High risk dusts ATEX 20 internal/21 external certified vacuum cleaners - Atex II 1/2D marking
  • Compressed air Atex certified vacuum cleaners for zone 1, 2, 21, 22 - Atex 2GD marking
  • Industrial vacuums for combustible dusts
  • INERT RANGE INDUSTRIAL VACUUM CLEANERS FOR COMBUSTIBLE DUST EXTRACTION for aluminum, inconal, lithium, tantalum or zirconium
  • PRE-SEPARATOR FOR THE INERTIZATION OF HAZARDOUS EXPLOSIVE DUSTS
  • Equipped with 1,1 to 18,5 kw single and three-phase motors
  • Vacuum till 4500 mm H2O
  • Tank capacity goes up to 220 liters
  • Wide range of available accessories
  • Extractable collection container
  • Cartrige filter elements with pneumatic jet celaning
  • HEPA filters
  • Compressed air driven units availabl


Your benefits at a glance:

  • Antistatic class M filters and grounding as standard
  • INERT RANGE units immerse material in an inert liquid
  • Three phase units available with side channel blower motor, powerful and silent, totally maintenance free, suitable for continuous duty
  • Single phase units equipped with brushless motors
  • Heavy duty steel construction
  • Filter with largest surface in its category equipped with integrated manual or automatic cleaning system
  • Pressure relief valve for motor protection
  • Vacuum gauge to detect filter clogging
  • Forklift straps
  • Easy filter replacement
  • Low noise level
  • Compact and mobile
  • Long lasting

Vacuum cleaner variants